IE (Ireland) Core Implementation Guide
1.0.0-ballot - Ballot
Publication Build: This will be filled in by the publication tooling
Page standards status: Trial-use | Maturity Level: 3 |
<ValueSet xmlns="http://hl7.org/fhir">
<id value="ie-core-specimen-condition"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ValueSet ie-core-specimen-condition</b></p><a name="ie-core-specimen-condition"> </a><a name="hcie-core-specimen-condition"> </a><a name="ie-core-specimen-condition-en-US"> </a><p>This value set includes codes based on the following rules:</p><ul><li>Import all the codes that are contained in <a href="http://terminology.hl7.org/5.5.0/ValueSet-v2-0493.html">hl7VS-specimenCondition</a></li><li>Include these codes as defined in <a href="http://www.snomed.org/"><code>http://snomed.info/sct</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="http://snomed.info/id/118127007">118127007</a></td><td>Sample lipemic (finding)</td></tr><tr><td><a href="http://snomed.info/id/118129005">118129005</a></td><td>Sample icteric (finding)</td></tr><tr><td><a href="http://snomed.info/id/125152006">125152006</a></td><td>Specimen satisfactory for evaluation (finding)</td></tr><tr><td><a href="http://snomed.info/id/125153001">125153001</a></td><td>Specimen satisfactory for evaluation but limited (finding)</td></tr><tr><td><a href="http://snomed.info/id/125159002">125159002</a></td><td>Sample unlabeled (finding)</td></tr><tr><td><a href="http://snomed.info/id/281263003">281263003</a></td><td>Sample leaked (finding)</td></tr><tr><td><a href="http://snomed.info/id/281265005">281265005</a></td><td>Sample incorrectly labeled (finding)</td></tr><tr><td><a href="http://snomed.info/id/281270003">281270003</a></td><td>Sample delayed in transit (finding)</td></tr><tr><td><a href="http://snomed.info/id/397212007">397212007</a></td><td>Specimen type not specified (finding)</td></tr><tr><td><a href="http://snomed.info/id/733480003">733480003</a></td><td>Sample decomposed (finding)</td></tr><tr><td><a href="http://snomed.info/id/84567002">84567002</a></td><td>Specimen obscured by blood (finding)</td></tr></table></li></ul></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="cgp"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
<valueInteger value="3">
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
<valueCanonical
value="http://iehr.ai/fhir/ie/core/ImplementationGuide/iehr.fhir.ie.core"/>
</extension>
</valueInteger>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
<valueCode value="trial-use">
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
<valueCanonical
value="http://iehr.ai/fhir/ie/core/ImplementationGuide/iehr.fhir.ie.core"/>
</extension>
</valueCode>
</extension>
<url
value="http://iehr.ai/fhir/ie/core/ValueSet/ie-core-specimen-condition"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:1.3.6.1.4.1.54392.5.2690.48.26"/>
</identifier>
<version value="1.0.0-ballot"/>
<name value="IECoreSpecimenCondition"/>
<title value="IE Core Specimen Condition"/>
<status value="active"/>
<experimental value="false"/>
<date value="2025-01-23T08:26:19-05:00"/>
<publisher value="iEHR.ai"/>
<contact>
<name value="iEHR.ai"/>
<telecom>
<system value="url"/>
<value value="http://www.iehr.ai"/>
</telecom>
<telecom>
<system value="email"/>
<value value="fhir@iehr.ai"/>
</telecom>
</contact>
<description
value="This value set contains concepts the provide information regarding a specimen, including the container, that does not meet a laboratory’s criteria for acceptability."/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="IE"/>
</coding>
</jurisdiction>
<copyright
value="This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
<compose>
<include>
<valueSet value="http://terminology.hl7.org/ValueSet/v2-0493"/>
</include>
<include>
<system value="http://snomed.info/sct"/>
<concept>
<code value="118127007"/>
<display value="Sample lipemic (finding)"/>
</concept>
<concept>
<code value="118129005"/>
<display value="Sample icteric (finding)"/>
</concept>
<concept>
<code value="125152006"/>
<display value="Specimen satisfactory for evaluation (finding)"/>
</concept>
<concept>
<code value="125153001"/>
<display
value="Specimen satisfactory for evaluation but limited (finding)"/>
</concept>
<concept>
<code value="125159002"/>
<display value="Sample unlabeled (finding)"/>
</concept>
<concept>
<code value="281263003"/>
<display value="Sample leaked (finding)"/>
</concept>
<concept>
<code value="281265005"/>
<display value="Sample incorrectly labeled (finding)"/>
</concept>
<concept>
<code value="281270003"/>
<display value="Sample delayed in transit (finding)"/>
</concept>
<concept>
<code value="397212007"/>
<display value="Specimen type not specified (finding)"/>
</concept>
<concept>
<code value="733480003"/>
<display value="Sample decomposed (finding)"/>
</concept>
<concept>
<code value="84567002"/>
<display value="Specimen obscured by blood (finding)"/>
</concept>
</include>
</compose>
</ValueSet>