IE (Ireland) Core Implementation Guide
1.0.0-ballot - Ballot
Publication Build: This will be filled in by the publication tooling
Official URL: http://iehr.ai/fhir/ie/core/StructureDefinition/ie-core-average-blood-pressure | Version: 1.0.0-ballot | |||
Standards status: Trial-use | Maturity Level: 3 | Computable Name: IECoreAverageBloodPressureProfile | ||
Other Identifiers: OID:1.3.6.1.4.1.54392.5.2690.42.5 | ||||
Copyright/Legal: iEHR.ai, all rights reserved Creative Commons License |
The IE Core Average Blood Pressure Profile inherits from the Observation resource; refer to it for scope and usage definitions. This profile sets minimum expectations for recording, searching, and fetching average diastolic and systolic blood pressure observations with standard LOINC codes and UCUM units of measure. It specifies which core elements, extensions, vocabularies, and value sets SHALL be present in the resource and constrains how the elements are used. Providing the floor for standards development for specific use cases promotes interoperability and adoption.
This page is new content for IE Core Version 1.0.0
Example Usage Scenarios:
The following are example usage scenarios for this profile:
The following data elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Views below provides the formal summary, definitions, and terminology requirements.
Each Observation Must Have:
Each Observation Must Support:
*see guidance below
Profile Specific Implementation Guidance:
a code system value SHOULD be supplied for each additional code.
Observation.value[x]
element SHALL be omittedObservation.component.dataAbsentReason
Observation.component.dataAbsentReason
for the components.Observation.note.text
(for example, "Average blood pressure is calculated from 12 measurements taken by the patient over three days.")Information about the number of measurements used to determine the average SHOULD be supplied as an Observation.component using the SNOMED CT code "246432004 |
Number of occurrences (qualifier value)". The example shows how this component can be used. |
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Observation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | Observation | IE Core Average Blood Pressure Profile | |
status | S | 1..1 | code | registered | preliminary | final | amended + |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation |
coding | S | 1..* | Coding | Code defined by a terminology system |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
code | S | 1..1 | CodeableConcept | Blood Pressure Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | S | 0..1 | Reference(IE Core Patient Profile) | Who and/or what the observation is about |
effective[x] | S | 1..1 | clinically relevant time-period for the average of blood pressure (BP) readings | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period S | |||
performer | S | 0..* | Reference(IE Core Practitioner Profile | IE Core Organization Profile | IE Core Patient Profile | PractitionerRole | IE Core CareTeam Profile | IE Core RelatedPerson Profile) | Who is responsible for the observation |
value[x] | 0..0 | |||
Slices for component | SC | 2..* | BackboneElement | Average systolic and diastolic blood pressure and other qualifiers. Slice: Unordered, Open by pattern:code ie-core-26: If there is no value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
value[x] | S | 0..1 | Vital Sign Component Value | |
valueQuantity | Quantity S | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing |
component:systolic | S | 1..1 | BackboneElement | Systolic Average Blood Pressure |
code | S | 1..1 | CodeableConcept | Systolic Average Blood Pressure Code Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
Slices for value[x] | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result Slice: Unordered, Open by type:$this | |
value[x]:valueQuantity | SC | 0..1 | Quantity S | Systolic Average Blood Pressure Value |
value | 1..1 | decimal | Numerical value (with implicit precision) | |
unit | 1..1 | string | Unit representation | |
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
code | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | |
component:diastolic | S | 1..1 | BackboneElement | Diastolic Average Blood Pressure |
code | S | 1..1 | CodeableConcept | Diastolic Average Blood Pressure Code Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
Slices for value[x] | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result Slice: Unordered, Open by type:$this | |
value[x]:valueQuantity | SC | 0..1 | Quantity S | Diastolic Average Blood Pressure Value |
value | 1..1 | decimal | Numerical value (with implicit precision) | |
unit | 1..1 | string | Unit representation | |
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
code | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | |
Documentation for this format |
Id | Grade | Path(s) | Details | Requirements |
ie-core-26 | error | Observation.component | If there is no value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | IE Core Average Blood Pressure Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | SΣ | 0..1 | Reference(IE Core Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣ | 1..1 | clinically relevant time-period for the average of blood pressure (BP) readings | |
effectivePeriod | Period | |||
performer | SΣ | 0..* | Reference(IE Core Practitioner Profile | IE Core Organization Profile | IE Core Patient Profile | PractitionerRole | IE Core CareTeam Profile | IE Core RelatedPerson Profile) | Who is responsible for the observation |
Slices for component | SΣC | 2..* | BackboneElement | Average systolic and diastolic blood pressure and other qualifiers. Slice: Unordered, Open by pattern:code ie-core-26: If there is no value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
value[x] | SΣ | 0..1 | Vital Sign Component Value | |
valueQuantity | Quantity | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:systolic | SΣ | 1..1 | BackboneElement | Systolic Average Blood Pressure |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Systolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Systolic Average Blood Pressure Value |
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | Σ | 1..1 | string | Unit representation |
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
component:diastolic | SΣ | 1..1 | BackboneElement | Diastolic Average Blood Pressure |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Diastolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Diastolic Average Blood Pressure Value |
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | Σ | 1..1 | string | Unit representation |
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:systolic.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:systolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:diastolic.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:diastolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ie-core-26 | error | Observation.component | If there is no value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | Observation | IE Core Average Blood Pressure Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 0..1 | Reference(IE Core Patient Profile) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣ | 1..1 | clinically relevant time-period for the average of blood pressure (BP) readings | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period S | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | SΣ | 0..* | Reference(IE Core Practitioner Profile | IE Core Organization Profile | IE Core Patient Profile | PractitionerRole | IE Core CareTeam Profile | IE Core RelatedPerson Profile) | Who is responsible for the observation | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 2..* | BackboneElement | Average systolic and diastolic blood pressure and other qualifiers. Slice: Unordered, Open by pattern:code ie-core-26: If there is no value a data absent reason must be present | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | SΣ | 0..1 | Vital Sign Component Value | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:systolic | SΣ | 1..1 | BackboneElement | Systolic Average Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Systolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity S | Systolic Average Blood Pressure Value | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | Σ | 1..1 | string | Unit representation | ||||
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:diastolic | SΣ | 1..1 | BackboneElement | Diastolic Average Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Diastolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity S | Diastolic Average Blood Pressure Value | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | Σ | 1..1 | string | Unit representation | ||||
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:systolic.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:systolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:systolic.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:systolic.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:diastolic.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:diastolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:diastolic.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:diastolic.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ie-core-26 | error | Observation.component | If there is no value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from Observation
Summary
Mandatory: 8 elements(8 nested mandatory elements)
Must-Support: 17 elements
Fixed: 6 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Slices
This structure defines the following Slices:
Maturity: 3
Differential View
This structure is derived from Observation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | Observation | IE Core Average Blood Pressure Profile | |
status | S | 1..1 | code | registered | preliminary | final | amended + |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation |
coding | S | 1..* | Coding | Code defined by a terminology system |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
code | S | 1..1 | CodeableConcept | Blood Pressure Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | S | 0..1 | Reference(IE Core Patient Profile) | Who and/or what the observation is about |
effective[x] | S | 1..1 | clinically relevant time-period for the average of blood pressure (BP) readings | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period S | |||
performer | S | 0..* | Reference(IE Core Practitioner Profile | IE Core Organization Profile | IE Core Patient Profile | PractitionerRole | IE Core CareTeam Profile | IE Core RelatedPerson Profile) | Who is responsible for the observation |
value[x] | 0..0 | |||
Slices for component | SC | 2..* | BackboneElement | Average systolic and diastolic blood pressure and other qualifiers. Slice: Unordered, Open by pattern:code ie-core-26: If there is no value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
value[x] | S | 0..1 | Vital Sign Component Value | |
valueQuantity | Quantity S | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing |
component:systolic | S | 1..1 | BackboneElement | Systolic Average Blood Pressure |
code | S | 1..1 | CodeableConcept | Systolic Average Blood Pressure Code Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
Slices for value[x] | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result Slice: Unordered, Open by type:$this | |
value[x]:valueQuantity | SC | 0..1 | Quantity S | Systolic Average Blood Pressure Value |
value | 1..1 | decimal | Numerical value (with implicit precision) | |
unit | 1..1 | string | Unit representation | |
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
code | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | |
component:diastolic | S | 1..1 | BackboneElement | Diastolic Average Blood Pressure |
code | S | 1..1 | CodeableConcept | Diastolic Average Blood Pressure Code Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
Slices for value[x] | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result Slice: Unordered, Open by type:$this | |
value[x]:valueQuantity | SC | 0..1 | Quantity S | Diastolic Average Blood Pressure Value |
value | 1..1 | decimal | Numerical value (with implicit precision) | |
unit | 1..1 | string | Unit representation | |
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
code | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | |
Documentation for this format |
Id | Grade | Path(s) | Details | Requirements |
ie-core-26 | error | Observation.component | If there is no value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | IE Core Average Blood Pressure Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | SΣ | 0..1 | Reference(IE Core Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣ | 1..1 | clinically relevant time-period for the average of blood pressure (BP) readings | |
effectivePeriod | Period | |||
performer | SΣ | 0..* | Reference(IE Core Practitioner Profile | IE Core Organization Profile | IE Core Patient Profile | PractitionerRole | IE Core CareTeam Profile | IE Core RelatedPerson Profile) | Who is responsible for the observation |
Slices for component | SΣC | 2..* | BackboneElement | Average systolic and diastolic blood pressure and other qualifiers. Slice: Unordered, Open by pattern:code ie-core-26: If there is no value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
value[x] | SΣ | 0..1 | Vital Sign Component Value | |
valueQuantity | Quantity | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:systolic | SΣ | 1..1 | BackboneElement | Systolic Average Blood Pressure |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Systolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Systolic Average Blood Pressure Value |
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | Σ | 1..1 | string | Unit representation |
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
component:diastolic | SΣ | 1..1 | BackboneElement | Diastolic Average Blood Pressure |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Diastolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Diastolic Average Blood Pressure Value |
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | Σ | 1..1 | string | Unit representation |
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:systolic.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:systolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:diastolic.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:diastolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ie-core-26 | error | Observation.component | If there is no value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | Observation | IE Core Average Blood Pressure Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 0..1 | Reference(IE Core Patient Profile) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣ | 1..1 | clinically relevant time-period for the average of blood pressure (BP) readings | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period S | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | SΣ | 0..* | Reference(IE Core Practitioner Profile | IE Core Organization Profile | IE Core Patient Profile | PractitionerRole | IE Core CareTeam Profile | IE Core RelatedPerson Profile) | Who is responsible for the observation | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 2..* | BackboneElement | Average systolic and diastolic blood pressure and other qualifiers. Slice: Unordered, Open by pattern:code ie-core-26: If there is no value a data absent reason must be present | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | SΣ | 0..1 | Vital Sign Component Value | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:systolic | SΣ | 1..1 | BackboneElement | Systolic Average Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Systolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity S | Systolic Average Blood Pressure Value | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | Σ | 1..1 | string | Unit representation | ||||
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:diastolic | SΣ | 1..1 | BackboneElement | Diastolic Average Blood Pressure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Diastolic Average Blood Pressure Code Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
Slices for value[x] | Σ | 0..1 | Actual component result Slice: Unordered, Open by type:$this | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity S | Diastolic Average Blood Pressure Value | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | Σ | 1..1 | string | Unit representation | ||||
system | ΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | Σ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:systolic.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:systolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:systolic.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:systolic.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:diastolic.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:diastolic.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:diastolic.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:diastolic.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
ie-core-26 | error | Observation.component | If there is no value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from Observation
Summary
Mandatory: 8 elements(8 nested mandatory elements)
Must-Support: 17 elements
Fixed: 6 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Slices
This structure defines the following Slices:
Maturity: 3
Other representations of profile: CSV, Excel, Schematron
Below is an overview of the required Server RESTful FHIR interactions for this profile - for example, search and read operations - when supporting the IE Core interactions to access this profile's information (Profile Support + Interaction Support). Note that systems that support only IE Core Profiles (Profile Only Support) are not required to support these interactions. See the IE Core Server CapabilityStatement for a complete list of supported RESTful interactions for this IG.
Servers providing access to vital signs data SHALL support these IE Core SMART Scopes:
resource level scopes: <patient|user|system>/Observation.rs
granular scopes: <patient|user|system>.Observation.rs?category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs
The following search parameters and search parameter combinations SHALL be supported:
SHALL support searching using the combination of the patient
and category
search parameters:
GET [base]/Observation?patient={Type/}[id]&category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and a category code = vital-signs
(how to search by reference and how to search by token)
patient
and code
search parameters:
code
(e.g.code={system|}[code],{system|}[code],...
)GET [base]/Observation?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and observation code(s). SHOULD support search by multiple codes. The Observation code
parameter searches `Observation.code only. (how to search by reference and how to search by token)
patient
and category
and date
search parameters:
date
comparators: gt,lt,ge,le
date
(e.g.date=[date]&date=[date]]&...
)GET [base]/Observation?patient={Type/}[id]&category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and date and a category code = vital-signs
(how to search by reference and how to search by token and how to search by date)
The following search parameter combinations SHOULD be supported:
patient
and category
and status
search parameters:
status
(e.g.status={system|}[code],{system|}[code],...
)GET [base]/Observation?patient={Type/}[id]&category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs&status={system|}[code]{,{system|}[code],...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and category and status (how to search by reference and how to search by token)
patient
and category
and _lastUpdated
search parameters:
_lastUpdated
comparators: gt,lt,ge,le
_lastUpdated
(e.g._lastUpdated=[date]&_lastUpdated=[date]]&...
)GET [base]/Observation?patient={Type/}[id]&category={system|}[code]&_lastUpdated={gt|lt|ge|le}[date]{&_lastUpdated={gt|lt|ge|le}[date]&...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and category and _lastUpdated. See the IE Core General Guidance page for Searching Using lastUpdated. (how to search by reference and how to search by token and how to search by date)
patient
and code
and date
search parameters:
code
(e.g.code={system|}[code],{system|}[code],...
)date
comparators: gt,lt,ge,le
date
(e.g.date=[date]&date=[date]]&...
)GET [base]/Observation?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example: